Portable Generator Safety: The 20-Foot Rule

Where the generator goes during an outage decides whether your family is safe. A practical guide to distance, wind direction, cords and the mistakes that cause most winter CO incidents.

By Dana Whitfield3 min read
In this guide
  1. Why twenty feet
  2. The garage rule
  3. Wind, exhaust and the direction nobody checks
  4. Where the alarm belongs
  5. Cords, load and the extension cord trap
  6. If the alarm sounds while the generator is running
  7. After the storm

Almost every generator-related carbon monoxide incident we read about follows the same script. The power goes out, the temperature drops, and the generator ends up somewhere it should never be: the attached garage, the covered porch, the carport, or just outside a basement window that happens to be open a crack.

The exhaust from a small gasoline generator contains carbon monoxide at concentrations that can reach lethal levels in a closed space within minutes. It is not a smell you will notice as a warning, because the gas has no smell at all.

Why twenty feet

The twenty-foot guidance exists because exhaust disperses with distance and air movement. Twenty feet from the house, away from doors, windows and vents, gives the plume room to dilute before it can be drawn back inside. Closer than that, and the outcome depends on wind, air pressure and which window is open, none of which you control during a storm.

  • Place the generator outdoors only, at least 20 feet (6 metres) from any door, window or vent.
  • Point the exhaust away from the building, not toward it.
  • Never run a generator in a garage, even with the door open. Attached garages share air with the house.
  • Keep it out from under eaves, decks and carports, where exhaust can pool.

The garage rule

An attached garage is not an outdoor space. It shares a wall, often a door, and usually a ceiling with living space above it. Carbon monoxide from a generator running in an open garage will migrate into the house through the door seal and any penetration for wiring or plumbing. Every winter we hear from someone who ran a generator in the garage for twenty minutes and set off the alarm inside the house. They were lucky the alarm worked.

Wind, exhaust and the direction nobody checks

Exhaust direction matters more than most people expect. On a still night, exhaust can settle and drift along a wall. On a windy night, it can be pushed straight back at the house. Check which way the tailpipe points after you start the unit, not before, and reposition if the plume is heading toward a window.

Where the alarm belongs

A generator changes your risk profile for the whole house, not just the room it sits beside. Put a CO alarm on every sleeping level, and one in any room that shares a wall with the garage.

A unit with a visible ppm display is genuinely useful during an outage, because you can see a small rise before it becomes an alarm.

Cords, load and the extension cord trap

  • Use an outdoor-rated cord rated for the full load, and keep the run as short as practical.
  • Never run a cord through a window or door that then stays partly open for hours; that opening is a path for exhaust.
  • Do not backfeed the house through a dryer outlet unless a transfer switch has been installed by an electrician.
  • Let the generator cool before refuelling, and never store fuel indoors.

If the alarm sounds while the generator is running

  1. Get everyone outside immediately and call 911.
  2. Shut the generator down only if you can do it safely on the way out.
  3. Do not re-enter to open windows or find the source.
  4. Wait for the fire department to clear the building before going back in.

After the storm

Once power returns, have a qualified technician inspect any fuel-burning appliance that ran during the outage, and replace the CO alarm backup battery if it has been chirping. Generators are safe tools when they stay outdoors and far enough away. The incidents happen in the twenty minutes when someone decides the garage is close enough.